Bosch
Bosch Climate 5000 L 4CC
Jednostka wewnętrzna · kasetonowy
Kod produktu: CL5000iU 4CC 35 E
KasetonowyTyp
3,5 kWChłodzenie
29 dBHałas (cichy)
Dane techniczne
acoustic
| Noise pressure indoor max dB(A) | 42 dBA |
|---|---|
| Noise pressure indoor medium dB(A) | 37,5 dBA |
| Noise pressure indoor min dB(A) | 34,5 dBA |
| Noise pressure indoor silent dB(A) | 28,5 dBA |
| Sound power indoor dB(A) | 57 dBA |
commercial
| Controller type | Standardowy bezprzewodowy enum_marker |
|---|
electrical
| Current cool max a | 6,31 A |
|---|---|
| Current cool min a | 1,32 A |
| Current cool nominal a | 4,45 A |
| Current heat max a | 6,07 A |
| Current heat min a | 1,04 A |
| Current heat nominal a | 4,73 A |
| Frequency supply hz | 50 Hz |
| Phase count | 1 szt |
| Power input cool max w | 1434 W |
| Power input cool min w | 168 W |
| Power input cool nominal w | 1010 W |
| Power input heat max w | 1376 W |
| Power input heat min w | 124 W |
| Power input heat nominal w | 1019 W |
| Voltage supply max v | 240 V |
| Voltage supply min v | 220 V |
hydraulic
| Condensate pipe outer diameter mm | 25 mm |
|---|---|
| Pipe diameter gas inch | 3/8 enum_marker |
| Pipe diameter gas mm | 9,52 mm |
| Pipe diameter liquid inch | 1/4 enum_marker |
| Pipe diameter liquid mm | 6,35 mm |
performance
| Airflow indoor max m3h | 569 m3h |
|---|---|
| Airflow indoor medium m3h | 485 m3h |
| Airflow indoor min m3h | 389 m3h |
| Dim depth indoor net mm | 570 mm |
| Dim depth indoor packaging mm | 670 mm |
| Dim height indoor net mm | 260 mm |
| Dim height indoor packaging mm | 325 mm |
| Dim width indoor net mm | 570 mm |
| Dim width indoor packaging mm | 670 mm |
| Weight indoor gross kg | 20,4 kg |
| Weight indoor net kg | 16,3 kg |