# LG DUALCOOL Standard — jednostka wewnętrzna

Pojedyncza jednostka wewnętrzna klimatyzatora split. Parametry z katalogu producenta — proweniencja: **pomiar/katalog**. Wartości nie zaokrąglane marketingowo.

## Dane podstawowe

| Parametr | Wartość |
|---|---|
| Marka | LG |
| Seria | DUALCOOL Standard |
| Model | H12S1PA.NS1 |
| EAN | — |
| Typ montażu | Ścienny |
| Moc chłodnicza (nom.) | 3,5 kW |
| Poziom hałasu (tryb cichy) | 19 dB(A) |
| Cena brutto | 1868,99 zł (zawiera VAT, + dostawa) |

## Pełna specyfikacja

### acoustic

| Parametr | Wartość |
|---|---|
| Noise pressure indoor cool max dB(A) | 47 dBA |
| Noise pressure indoor cool min dB(A) | 27 dBA |
| Noise pressure indoor heat max dB(A) | 48 dBA |
| Noise pressure indoor heat min dB(A) | 27 dBA |
| Noise pressure indoor silent dB(A) | 19 dBA |
| Sound power indoor dB(A) | 60 dBA |

### capacity

| Parametr | Wartość |
|---|---|
| Dehumidification l h | 1,3 l/h |

### electrical

| Parametr | Wartość |
|---|---|
| Current cool max a | 6,5 A |
| Current cool min a | 1,3 A |
| Current cool nominal a | 3,75 A |
| Current heat max a | 7,5 A |
| Current heat min a | 1,3 A |
| Current heat nominal a | 4 A |
| Phase count | 1 szt |
| Power input cool max w | 1500 W |
| Power input cool min w | 160 W |
| Power input cool nominal w | 815 W |
| Power input heat max w | 1750 W |
| Power input heat min w | 160 W |
| Power input heat nominal w | 850 W |
| Voltage supply max v | 240 V |
| Voltage supply min v | 220 V |

### hydraulic

| Parametr | Wartość |
|---|---|
| Condensate pipe inner diameter mm | 16 mm |
| Condensate pipe outer diameter mm | 21,5 mm |
| Pipe diameter gas mm | 9,52 mm |
| Pipe diameter liquid mm | 6,35 mm |

### performance

| Parametr | Wartość |
|---|---|
| Airflow indoor cool max m3h | 816 m3h |
| Airflow indoor heat max m3h | 852 m3h |
| Dim depth indoor net mm | 235 mm |
| Dim height indoor net mm | 307 mm |
| Dim width indoor net mm | 895 mm |
| Weight indoor net kg | 12,6 kg |

---
Źródło: PlanetClimaten — dane oparte na katalogach producentów (Eurovent, EPREL).